MODEL | | ELG-240-24 | ELG-240-36 | ELG-240-42 | ELG-240-48 | ELG-240-54 |
OUTPUT | DC VOLTAGE | 24V | 36V | 42V | 48V | 54V |
CONSTANT CURRENT REGION Note.2 | 12 ~ 24V | 18 ~ 36V | 21 ~ 42V | 24 ~ 48V | 27 ~ 54V |
RATED CURRENT | 10A | 6.66A | 5.71A | 5.0A | 4.45A |
RATED POWER Note.5 | 240W | 239.76W | 239.82W | 240W | 240.3W |
RIPPLE & NOISE (max.) Note.3 | 200mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 350mVp-p |
VOLTAGE ADJ. RANGE | Adjustable for A-Type only (via built-in potentiometer) |
22.4 ~ 25.6V | 33.5 ~ 38.5V | 39 ~ 45V | 44.8 ~ 51.2V | 50 ~ 57V |
CURRENT ADJ. RANGE | Adjustable for A-Type only (via built-in potentiometer) |
5 ~ 10A | 3.33 ~ 6.66A | 2.86 ~ 5.71A | 2.5 ~ 5A | 2.23 ~ 4.45A |
VOLTAGE TOLERANCE Note.4 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
SETUP, RISE TIME Note.6 | 500ms, 100ms/230VAC, 1000ms, 100ms/115VAC |
HOLD UP TIME (Typ.) | 10ms/ 230VAC 10ms/ 115VAC |
INPUT | VOLTAGE RANGE Note.5 | (Please refer to "STATIC CHARACTERISTIC" section) 100 ~ 305VAC 142 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
POWER FACTOR | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load >= >= >= (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) |
TOTAL HARMONIC DISTORTION | THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)>= >= (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section) |
EFFICIENCY (Typ.) | 92% | 92% | 92.5% | 93% | 93% |
AC CURRENT | 2.2A / 115VAC 1.5A / 230VAC 1.2A/277VAC |
INRUSH CURRENT(Typ.) | COLD START 60A(twidth=510μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC |
LEAKAGE CURRENT | <0.75mA / 277VAC |
NO LOAD / STANDBY POWER CONSUMPTION Note.7 | No load power consumption <0.5W for Blank / A / Dx / D-Type Standby power consumption <0.5W for B / DA-Type |
PROTECTION | OVER CURRENT | 95 ~ 108% |
Constant current limiting, recovers automatically after fault condition is removed |
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE | 27 ~ 34V | 42 ~ 49V | 47 ~ 54V | 54 ~ 63V | 60 ~ 67V |
Shut down output voltage, re-power on to recover |
OVER TEMPERATURE | Shut down output voltage, re-power on to recover |
ENVIRONMENT | WORKING TEMP. | Tcase=-40 ~ +90ºC (Please refer to " OUTPUT LOAD vs TEMPERATURE" section) |
MAX. CASE TEMP. | Tcase=+90ºC |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40 ~ + , 10 ~ 95% RH 90ºC |
TEMP. COEFFICIENT | ± ºC ºC0.03%/ (0 ~ 60 ) |
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
SAFETY & EMC | SAFETY STANDARDS | UL8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.14,GB19510.1; IP65 or IP67 approved |
DALI STANDARDS | Compiy with IEC62386-101,102,207 for DA-Type only |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH |
EMC EMISSION | Compliance to EN55015,EN61000-3-2 Class C (@load>=50%) ; EN61000-3-3;GB17625.1,GB17743 |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV) |
OTHERS | MTBF | 826.7K hrs min. Telcordia SR-332 (Bellcore) ; 200.8Khrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 244 71* *37.5mm (L*W*H) |
PACKING | 1.05Kg; 12pcs / 13.6Kg / 0.72CUFT |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 ol ambient temperature. current ºC 2. Please reler to "DRIVING METHODS OF LED MODULE". 3. Ripple & noise are measured at 20MHz ol bandwidth by using a 12" twisted pair-wire terminated with a 0.1ul & 47ul parallel capacitor.4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. De rating may be needed under low input voltages. Please .-reler to "STATIC CHARACTERISTIC" sections lor details 6. Length ol set up time is measured at lirst cold start. Turning ON/OFF the driver may lead to increase ol the set up time. 7. No load/standby power consumption is specilied lor 230VAC input. 8. The driver is considered as a component that will be operated in combination with linal equipment. Since EMC perlormance will be allected by the complete installation, the linal equipment manulacturers must re-qualily EMC Directive on the complete installation again.9. This series meets the typical lile expectancy ol >50,000 hours ol operation when Tcase, particularly t c point (or TMP, per DLC), is about 70 ºC or less. 10. Please reler to the warranty statement on MEAN WELL's website at http://www.meanwell.com |